ATI A12-17 Combustible Gas Transmitter

ATI's A12-17 combustible gas transmitter performs an automatic gas test every 24 hours, eliminating the need for frequent response checks.

Features

  • Transmitters contain an LCD display indicating LEL values locally
  • Magnetic transmitter controls allow adjustments without removing enclosure cover
  • Hydrogen generator may be activated manually on command to observe sensor response
Your Price Call
Stock Drop Ships From Manufacturer  
Combustible Gas Detectors are used in a wide variety of industrial plants to detect gas leakage or buildup before it reaches explosive levels. These detectors rely on thermal oxidation of any combustible gas or vapor on the surface of a heated catalyst. In other words, they simply burn the gas and measure the heat released in the combustion process.

While this type of sensor is generally stable and reliable, it is also subject to poisoning by silicon vapor, lead compounds, and other environmental contaminants. To detect loss of sensitivity, most users test combustible sensors either weekly or biweekly to ensure response. The procedure is simple, but requires manpower to perform the test.

ATI's Auto-Test Combustible Gas Transmitter eliminates the need for frequent response checks. This transmitter performs an automatic gas test on the sensing element every 24 hours. The result is a combustible gas detector system with a level of reliability beyond that of any other system available. This daily sensor response verification is as close to a fail-safe detection system as you can find, with the added benefit of greatly reduced manual testing.

Combustible gas sensors are made up of two matched sensing elements, one active and one passive. Both are electrically heated and form two legs of a Wheatstone bridge circuit. When combustible gas contacts the sensor, the active element catalyzes the oxidation of gas, heating the active element and changing its resistance. The passive element remains unchanged, resulting in a change in the bridge circuit that is proportional to the gas concentration. As long as the active element remains in good condition, the sensor will respond rapidly to the presence of combustible gas.

The Auto-Test sensor is actually a combination of a gas sensor and an electrochemical hydrogen gas generator (patent pending) integrated into an explosion-proof stainless steel housing. When activated by the electronic transmitter, the generator produces hydrogen that diffuses to the gas sensor through the flame arrestor protecting the sensor. If the sensor responds properly, the transmitter will show a "Pass" indication. Should the sensor not respond properly, an "Auto Test Fail" message will activate at the transmitter and the 4-20 mA output from the transmitter will drop to 3 mA, providing for remote fault indication.
Questions & Answers
No Questions
Please, mind that only logged in users can submit questions

Select Options

  Products 0 Item Selected
Image
Part #
Description
Price
Stock
Quantity
ATI A12-17 Combustible Gas Transmitter
A12-17
Combustible gas transmitter
Request Quote
Drop Ships From Manufacturer  
Notice: At least 1 product is not available to purchase online
Ɨ
Multiple Products

have been added to your cart

There are items in your cart.

Cart Subtotal: $xxx.xx

Go to Checkout

In The News

Collaborative Southeast Nexus study examines region's air quality

While much of the world has experienced a warmer climate in recent years, the U.S. Southeast has cooled. Scientists want to know why because the answer could reveal keys to improving air quality and understanding climate change. To study the cooling Southeast, scientists at several institutions have joined forces to conduct the Southern Atmosphere Study (SAS), the largest study on southeastern U.S. air quality since the 1990s. These include the U.S. Environmental Protection Agency, National Center for Atmospheric Research, National Science Foundation, National Oceanic and Atmospheric Administration and the Electric Power Research Institute. Five air quality studies fall under the SAS umbrella.

Read More

Wash. State to chart methane emissions from gas utilities

Researchers at Washington State University will quantify uncombusted methane emissions throughout the U.S., according to a release. The investigators will look at emissions from local gas systems and try to estimate a national emissions rate. Uncombusted natural gas is more harmful to the atmosphere than carbon dioxide because it has a higher warming potential. Emissions of uncombusted methane along the natural gas supply line haven’t been measured on a national scale and studying them will become more important as the U.S. natural gas industry continues to expand. The Washington State study begins in April and is funded by major natural gas utilities, the Environmental Defense Fund and Conestoga-Rovers and Associates, an environmental engineering and consulting firm.

Read More

Vancouver gets new air monitoring vehicle

A new air monitoring vehicle was recently delivered to the city of Vancouver with praise and skepticism from metropolitan residents, according to The Province. The vehicle, known as the Mobile Air Monitoring Unit, is loaded with sensors which will monitor air quality.  The city wants to monitor particulates in the air from coal, diesel and oil tankers. Data collected by the truck transmits to the city hall. Some citizens are happy to have a new mobile air monitoring station that will supplement the city’s 26 stationary monitoring stations. However, many citizens criticized the loaded Ford F-450’s price tag of more than $280,000.

Read More