Extech EasyView Dual Input Thermometer

The Extech EasyView Dual Input Thermometer measures a wide range of temperature points.

Features

  • Records max/min readings for later recall
  • Data Hold function freezes reading on display
  • Selectable units of °F, °C, K (Kelvin)
Starting At $146.99
Stock Check Availability  

The Extech EasyView Dual Input Thermometer Displays [T1 plus T2] or [T1-T2 plus T1] or [T1-T2 plus T2] temperature readings. The selectable units of °F, °C,  and K offer a wide temperature range with 0.1°/1° resolution. The timer function displays elapsed time plus time when min and max readings are taken. The data hold function freezes readings on the display for further analysis, and the unit records max/min readings for later recall.

 

Model EA10 features basic type K dual input and includes an OFFSET key used for zero function to make relative measurements. Model EA15 features dual inputs that accept types J, K, E, T, R, S, and N thermocouples, and has a built-in datalogger that stores up to 8800 data sets. The RS-232 port allows data to be easily transported to a PC for analysis. The datalogger comes with Windows compatible software and cable.

EA10

 

  • Type K range: -200 to 1999°F (-200 to 1360°C)
  • Resolution:  0.1°
  • Basic accuracy: ±0.3% (+2°F/+1°C)
  • Dimensions: 6 x 2.8 x 1.5" (152 x 72 x 37mm)
  • Weight: 8.3oz (235g)

 

EA15

 

  • Type J range: -200 to 1994°F (-150 to 1090°C)
  • Type K range: -200 to 1999.9°F (-150 to 1370°C)
  • Type T range: -200 to 752°F (-150 to 400°C)
  • Type E range: -200 to 1598°F (-150 to 870°C)
  • Type R range: 35 to 1999.9°F (2 to 1767°C)
  • Type S range: 35 to 1999.9°F (2 to 1767°C)
  • Type N range: -200 to 1999.9°F (-150 to 1300°C)
  • Resolution: 0.1°
  • Types J, K, E, T, N basic accuracy: ±0.05% rdg (+1.5°F/+0.75°C)
  • Types R, S basic accuracy: ±0.05% rdg (+4°F/+2°C) Types R,S
  • Dimensions: 6 x 2.8 x 1.5" (152 x 72 x 37mm)
  • Weight: 8.3oz (235g)
  • (1) Thermometer
  • (1) Built-in stand
  • (1) Protective holster
  • (2) Type K bead wire temperature probes
  • (6) AAA batteries
  • (1) Software (EA15)
  • (1) Cable (EA15)
Questions & Answers
No Questions
Please, mind that only logged in users can submit questions

Select Options

  Products 0 Item Selected
Image
Part #
Description
Price
Stock
Quantity
Extech EasyView Dual Input Thermometer
EA10
EasyView dual input thermometer
Your Price $146.99
Check Availability  
Extech EasyView Dual Input Thermometer
EA10-NIST
EasyView dual input thermometer, NIST traceable
$225.99
Check Availability  
Extech EasyView Dual Input Thermometer
EA15
EasyView dual input thermometer + datalogger
$293.99
Check Availability  
Extech EasyView dual input temperature datalogger (with NIST Certificate)
EA15-NIST
EasyView dual input thermometer + datalogger, NIST traceable
$398.99
Check Availability  
Notice: At least 1 product is not available to purchase online
×
Multiple Products

have been added to your cart

There are items in your cart.

Cart Subtotal: $xxx.xx

Go to Checkout

In The News

Applied Research and Innovative Solutions: Creating CHNGES at Western Kentucky University

Long-standing environmental monitoring programs have the power to support a large number of research initiatives and policy changes—however, actually starting these networks can prove challenging. Not only is starting the program difficult, but keeping things operational for decades to come has also been challenging for environmental professionals hoping to make an impact with applied research. Jason Polk, Professor of Environmental Geoscience and Director of the Center for Human GeoEnvironmental Studies (CHNGES) at Western Kentucky University, is all too familiar with this process.

Read More

Combating Water Insecurity in Saskatchewan with Real-Time Data

The prairies of Saskatchewan can be described as one of the least water-secure parts of Canada, making water quality monitoring essential for informed resource management in a region already facing water insecurity. While natural physical properties worsen some of the poor water quality conditions in the region, others are connected to land use. Having grown up spending summers on the shores of Lake Huron, Helen Baulch, an associate professor at the School of Environment and Sustainability at the University of Saskatchewan , has always been dedicated to the protection of water resources. Looking back fondly at her childhood playing along the shore, Baulch also recalls the invasion of quagga mussels during her teenage years and watching the lake change as a result.

Read More

Seametrics Turbo Turbidity Logger: Boost your Turbidity Monitoring

The Seametrics Turbo Turbidity Logger is a self-cleaning turbidity sensor capable of internally logging over 260,000 data records. The sensor enables researchers, compliance officers, and contractors to monitor turbidity in various applications, from construction and dredging sites to wastewater effluent.  Due to its narrow width, this device can be deployed in a range of areas, from small well spaces to rivers and streams. The stainless steel housing and built-in wiper allow the sensor to withstand long-term deployments and reduce the need for maintenance trips.  The logger accurately records temperature and turbidity up to a depth of 50 meters.

Read More