Onset HOBO UX120 4-Channel Thermocouple Logger
Features
- Records temperatures from -260 to 1820⁰C
- Accepts up to four J, K, T, E, R, S, B, or N type probes
- Internal temperature sensor for logging ambient temperatures
- Expedited repair and warranty service
- Lifetime technical support
- More
Overview
The Onset HOBO UX120 4-Channel Thermocouple Logger is a four-channel thermocouple LCD data logger that measures and records temperature in a broad range of monitoring applications. Records temperatures from -260 to 1820⁰ C and accepts up to four J, K, T, E, R, S, B, or N type probes. This logger also features an internal temperature sensor for logging ambient temperatures, further extending the range of application possibilities.
LCD Display
Easy-to-view LCD display confirms logger operation and battery status in addition to alarms for exceeding temperature thresholds, and a near real-time readout of current temperatures as well as minimum, maximum, average and standard deviation statistics.
Benefits
- Large memory capacity capable of storing 1.6 million measurements
- Start, stop, and restart pushbuttons
- User upgradeable firmware
- Optional protective case enables logger use in outdoor environments
- Compatible with HOBOware and HOBOware Pro software for logger setup, graphing, and analysis
Internal Temperature
Range |
-20° to 70°C (-4° to 158°F) |
Accuracy |
±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F) |
Resolution |
0.024°C at 25°C (0.04°F at 77°F) |
Drift |
<0.1°C (0.18°F) per year |
Logger
Logging Rate |
1 second to 18 hours |
Logging Modes |
Normal, Burst, Statistics |
Memory Modes |
Wrap when full or stop when full |
Time Accuracy |
±1 minute per month at 25°C (77°F) |
Battery Life |
1 year typical with logging rate of 1 minute and sampling interval of 15 seconds or greater, user replaceable, 2 AAA |
Dimensions |
10.8 x 5.41 x 2.54 cm (4.25 x 2.13 x 1 in.) |
Operating Range |
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing) |
CE Compliant |
Yes |
Thermocouple
Type J |
-210° to 760°C (-346° to 1,400°F) |
±0.6°C (±1.08°F) ± thermocouple probe accuracy |
0.03°C (0.06°F) |
Type K |
-260° to 1,370°C (-436° to 2,498°F) |
±0.7°C (±1.26°F) ± thermocouple probe accuracy |
0.04°C (0.07°F) |
Type T |
-260° to 400°C (-436° to 752°F) |
±0.6°C (±1.08°F) ± thermocouple probe accuracy |
0.02°C (0.03°F) |
Type E |
-260° to 950°C (-436° to 1,742°F) |
±0.6°C (±1.08°F) ± thermocouple probe accuracy |
0.03°C at (0.05°F) |
Type R |
-50° to 1,550°C (-58° to 2,822°F) |
±2.2°C (±3.96°F) ± thermocouple probe accuracy |
0.08°C (0.15°F) |
Type S |
-50° to 1,720°C (-58° to 3,128°F) |
±2.2°C (±3.96°F) ± thermocouple probe accuracy |
0.08°C (0.15°F) |
Type B |
550° to 1,820°C (1,022° to 3,308°F) |
±2.5°C (±4.5°F) ± thermocouple probe accuracy |
0.1°C (0.18F) |
Type N |
-260° to 1,300°C (-436° to 2,372°F) |
±1.0°C (±1.8°F) ± thermocouple probe accuracy |
0.06°C (0.11°F) |
- HOBO UX120-014M 4-Channel Thermocouple Data Logger
- Command strip
- Double-sided tape
- Hook & loop strap
- Two AAA 1.5 V alkaline batteries
In The News
Applied Research and Innovative Solutions: Creating CHNGES at Western Kentucky University
Long-standing environmental monitoring programs have the power to support a large number of research initiatives and policy changes—however, actually starting these networks can prove challenging. Not only is starting the program difficult, but keeping things operational for decades to come has also been challenging for environmental professionals hoping to make an impact with applied research. 
 
Jason Polk, Professor of Environmental Geoscience and Director of the Center for Human GeoEnvironmental Studies (CHNGES) at Western Kentucky University, is all too familiar with this process.
Read MoreCombating Water Insecurity in Saskatchewan with Real-Time Data
The prairies of Saskatchewan can be described as one of the least water-secure parts of Canada, making water quality monitoring essential for informed resource management in a region already facing water insecurity. While natural physical properties worsen some of the poor water quality conditions in the region, others are connected to land use. 
 
Having grown up spending summers on the shores of Lake Huron, Helen Baulch, an associate professor at the School of Environment and Sustainability at the University of Saskatchewan , has always been dedicated to the protection of water resources. 
 
Looking back fondly at her childhood playing along the shore, Baulch also recalls the invasion of quagga mussels during her teenage years and watching the lake change as a result.
Read MoreSeametrics Turbo Turbidity Logger: Boost your Turbidity Monitoring
The Seametrics Turbo Turbidity Logger is a self-cleaning turbidity sensor capable of internally logging over 260,000 data records. The sensor enables researchers, compliance officers, and contractors to monitor turbidity in various applications, from construction and dredging sites to wastewater effluent. 
 
 Due to its narrow width, this device can be deployed in a range of areas, from small well spaces to rivers and streams. The stainless steel housing and built-in wiper allow the sensor to withstand long-term deployments and reduce the need for maintenance trips. 
 
 The logger accurately records temperature and turbidity up to a depth of 50 meters.
Read More